⚡ANMASystem BuildingAutomation, Network, Monitoring & Analytics
★PREMIUM

Knowledge Base › Microinverters

NEP (Northern Electric Power) BDM-1600-LV

Official manufacturer GLOBAL verified Sept. 22, 2026

Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.

Identity

category microinverters
ean —
firmware {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'}
generation —
manufacturer NEP (Northern Electric Power)
market_version —
model BDM-1600-LV
mpn —
product_family BDM-1200-LV / BDM-1600-LV
product_status active
region GLOBAL
release_year —
series —
sku —

Electrical

ac_voltage_range —
cec_efficiency_pct —
euro_efficiency_pct 96.5
european_efficiency_pct —
frequency_range_hz —
max_ac_current_a —
max_apparent_power_va —
max_dc_input_power_w —
max_dc_voltage_v 60
max_efficiency_pct —
max_input_current_per_input_a 25
NEP BDM-1200-LV / BDM-1600-LV Microinverter Datasheet (250723)
max_input_current_per_mppt_a —
max_short_circuit_current_per_mppt_a —
mppt_count 2
mppt_voltage_max_v 55
NEP BDM-1200-LV / BDM-1600-LV Microinverter Datasheet (250723)
mppt_voltage_range_max_v 60.0
mppt_voltage_range_min_v 16.0
mppt_voltage_range_v 22~55V
nominal_ac_voltage 120V
nominal_ac_voltage_v 230.0
nominal_frequency_hz —
number_of_mppt 1
number_of_pv_inputs —
phase_count 1
pv_input_voltage_max_v 60
NEP BDM-1200-LV / BDM-1600-LV Microinverter Datasheet (250723)
pv_input_voltage_min_v 20
NEP BDM-1200-LV / BDM-1600-LV Microinverter Datasheet (250723)
rated_ac_power_w 1600
startup_voltage_v 25
NEP BDM-1200-LV / BDM-1600-LV Microinverter Datasheet (250723)
units_per_branch —

Physical / mechanical

ac_terminal —
cooling —
dc_connector —
depth_mm —
dimensions_mm —
display —
enclosure_material —
height_mm —
mounting —
noise_db —
weight_kg —
width_mm —

Installation

cable_requirements —
commissioning —
installation_angle —
mounting_clearances —
torque —

Environment

ingress_protection NEMA-6/IP-66/IP-67
ip_rating IP67
max_altitude_m —
operating_temperature_c —
operating_temperature_max_c 60.0
operating_temperature_min_c -25.0
pollution_degree —
protective_class —
relative_humidity_pct —
storage_temperature_c —

Interfaces & connectors

app —
communication [] disputed
dry_contact —
meter_interface —
monitoring_portal —
protocols []

Protection

anti_islanding —
arc_fault —
dc_switch —
insulation_monitoring —
overvoltage_category —
rcmu —
reverse_polarity —
surge_protection_ac —
surge_protection_dc —

Warranty & service

conditions —
extension_options —
standard_years —
warranty_years 12

Documents

datasheet NEP BDM-1200-LV / BDM-1600-LV Features + UL Certs sheet (BDM-1200-LV-250723) rev BDM-1200-LV-250723 (July 23 2025)
datasheet NEP BDM-1200-LV / BDM-1600-LV Microinverter Datasheet (250723)
manual NEP [EN_MANUAL] BDM-1200LV User Manual (Technical Data section) rev posted 2025-09
product-page BDM-1200-LV / BDM-1600-LV | NEP microinverters
product-page Microinverters | NEP - Northern Electric Power rev UNKNOWN
product_page NEP Europe BDM-1200-LV/BDM-1600-LV product page (technical data table, both model columns)

Recorded conflicts

max_input_current_per_input_a Review required
None — value currently stored in ANMA
25 — https://eu.northernep.com/proinfo/31.html
document-revision
ingress_protection Review required
NEMA-6/IP-66/IP-67 — value currently stored in ANMA
NAME 4X — https://eu.northernep.com/proinfo/31.html
document-revision
rated_ac_power_w Review required
1600 — value currently stored in ANMA
1200 — https://eu.northernep.com/proinfo/31.html
document-revision
interfaces.communication Review required
[] — stored value
['Power line communication'] — incoming package
Detected during import wave8-saturation-2026-09-batch10

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

BDM-1200-LV UL-certs sheet, 'Recommended PV Module Max. Power' / 'Max. PV Current' / 'Start-up Voltage' / 'Rated AC Output Current'600 W x 3 / 25 A x 3 / 25 V / 10 A @ 120 V
BDM-1200LV User Manual mechanical/communication268 x 250 x 46.5 mm; 3.4 kg; PLC or Wi-Fi (2.4G); Night Power Consumption 110 mW
BDM-1200LV User Manual, 'AC Short Circuit Fault Current Over 3 cycles / Arms'15.3
BDM-1200LV User Manual, 'Max. Input Current / A'18 x 3
BDM-1200LV User Manual, 'Recommended PV Module Power Range / W'500 x 3
EfficiencyUp to 95.5% CEC
Max Current12 Amps
Max PV current / No. of inputs25A×4 / No. of inputs: 4
Maximum short-circuit current (Isc)NOT PRINTED
NEP Europe efficiency rowsMax MPPT Efficiency 99.9%; Max Efficiency 97.5%
Operating Temperature-40°F to +185°F
Rated AC Output Current13.3A
Sibling family for context: BDM-1200/1600/2000-WF QUAD manual'four independent DC input ports' / 'four sets of two oppositely sexed DC connectors'; 25A x 4 Isc; no tracker count
category index card titleBDM-1200-LV/BDM-1600-LV
withheld:ac.max_ac_power_w_detail"'Peak Output Power / VA 1200' is printed only in the BDM-1200LV User Manual, which has no BDM-1600-LV column; carried here as the family figure NEP publishes and flagged, since the EU table gives the BDM-1600-LV the same 1200 W rating."
withheld:ac.rated_ac_power_w1200
withheld:ac.rated_ac_power_w_detail"SOURCE VALUE. NEP Europe prints '1200' W in the BDM-1600-LV column, identical to the BDM-1200-LV column. ANMA holds 1600 W. See conflicts - ANMA's value was NOT overwritten by me; this field records what the source says."
withheld:dc.max_input_current_per_input_a25
withheld:safety.ingress_protection"NAME 4X [printed exactly so on NEP Europe; evident typo for NEMA 4X] / IP66-IP67 per the BDM-1200LV User Manual"
withheld:topology.max_units_per_ac_branch_detail"Not published for the BDM-1600-LV; the BDM-1200LV User Manual's 'Max. Units per 20A Branch 1' belongs to the BDM-1200-LV column and was not carried across."
withheld:topology.mppt_independence_detail"NOT PUBLISHED. NEP Europe prints an explicit 'Number of Inputs' row (4 for the BDM-1600-LV) but no MPP-tracker count; the BDM-1200LV User Manual and the BDM-1200-LV UL-certs sheet were both re-read with a verbatim-quote prompt and neither states a tracker count either (the UL sheet's only MPPT rows