Knowledge Base › Microinverters
Sparq Systems Q1200-4102
Official manufacturer APAC verified Sept. 23, 2026
Identity
| category | microinverters |
| manufacturer | Sparq Systems |
| model | Q1200-4102 |
| region | APAC |
Electrical
| ac_grid_connection_types |
['230V L-N from 1-ϕ']
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| branch_conductor |
10 AWG (6mm2) Trunk
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| gateway_required |
True
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| grid_frequency_hz |
50
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| max_efficiency_percent |
97
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| max_input_current_a |
16
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| max_input_current_axis |
per channel
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| max_units_per_branch |
5
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| mppt_voltage_extended_max_v |
50
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| mppt_voltage_extended_min_v |
20
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| mppt_voltage_max_v |
47
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| mppt_voltage_min_v |
23
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| number_of_pv_inputs |
4
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| official_manual_url |
https://www.sparqsys.com/Q1200/Q1200-Installer-India.pdf
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102 — inventory record source_url
|
| phase_count |
1
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| rated_ac_power_w |
1200
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| recommended_module_power_max_w |
400
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| required_gateway |
SparqLinq
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
Physical / mechanical
| height_mm |
32
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| length_mm |
285
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| weight_kg |
3.3
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
| width_mm |
186
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
Interfaces & connectors
| communications |
['Wireless']
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
|
Documents
installation_manual
The Q1200 Microinverter Installation Manual for India - Model Q1200-4102
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| builder_completeness | partial |
| region_notes | India edition installation manual (cover: 'The Q1200 Microinverter Installation Manual for India Model Q1200-4102'); the grid connection row reads 230V L-N from 1-phase at 50 Hz. Market: India. Other market editions of the same model code may exist but were not opened. |