⚡ANMASystem BuildingAutomation, Network, Monitoring & Analytics
★PREMIUM

Knowledge Base › Microinverters

Sparq Systems Q2000-4102

Official manufacturer NA verified Sept. 23, 2026

Identity

category microinverters
manufacturer Sparq Systems
model Q2000-4102
product_status active
region NA

Electrical

ac_connector T5 AC micro male connector
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
ac_grid_connection_types ['208V L-L (3-phase)', '240V L-L (split-phase)', '230V L-N (1-phase)']
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
branch_conductor 10 AWG (6mm2) Trunk
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
cec_efficiency_percent 97
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
euro_efficiency_pct 96.5
gateway_required True
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
grid_frequency_hz 60
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
max_dc_voltage_v 60.0
max_efficiency_pct 96.7
max_efficiency_percent 97.5
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
max_input_current_per_mppt_a 16.0
max_short_circuit_current_per_mppt_a 25.0
max_units_per_branch 3
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
mppt_count 4
mppt_voltage_max_v 60
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
mppt_voltage_min_v 19
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
nominal_ac_voltage_v 230.0
nominal_frequency_hz 50.0
number_of_mppt 4
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
number_of_pv_inputs 4
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
phase_count 1
rated_ac_power_w 2000
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
recommended_module_power_max_w 680
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
required_gateway SparqLinq
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102

Physical / mechanical

height_mm 32
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
length_mm 285
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
weight_kg 3.3
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
width_mm 186
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102

Environment

enclosure_rating NEMA 6, IP 67
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
ip_rating IP67
operating_temperature_max_c 65
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
operating_temperature_min_c -40
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102

Interfaces & connectors

communications ['Wireless', 'ZigBee']
The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102

Warranty & service

warranty_years 12

Documents

installation_manual The Q2000 Microinverter Installation Manual for North America - Model Q2000-4102
product_page Quad2 Microinverter

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

builder_completenesspartial
region_notesNorth America edition installation manual (cover: 'The Q2000 Microinverter Installation Manual for North America Model Q2000-4102'); the manual covers 208 V L-L, 240 V L-L and 230 V L-N grid types. An India edition of the same model code exists (listed in search results) but was not opened.