PRODUCT PHOTO · AlicoSolar
Identity
| aliases |
['MPPT-384V-80A', 'MPPT-384V-100A']
|
| brand |
AlicoSolar
|
| category |
mppt_controllers
|
| manufacturer |
AlicoSolar
|
| manufacturer_key |
alicosolar
|
| model |
384V MPPT Solar Charge Controller
|
| model_key |
384v-mppt-solar-charge-controller
|
| product_status |
active
|
| region |
GLOBAL
|
Electrical
| battery_voltage_range_v |
288-512 VDC
|
| charge_method |
3-stage (CC/CV/Float)
|
| charge_mode |
MPPT (efficiency >99.5%)
|
| input_low_voltage_protection |
Battery voltage +10V
|
| max_pv_input_voltage_v |
850
|
| models |
['MPPT-384V-80A', 'MPPT-384V-100A']
|
| rated_charge_current_a |
[80, 100]
|
| rated_pv_input_power_w |
{'80A': 33280, '100A': 35800}
|
| selectable_battery_types |
['Sealed Lead-Acid', 'Vented', 'Gel', 'Ni-Cd']
|
| start_charging |
Battery voltage +20V
|
| system_voltage_v |
384
|
Physical / mechanical
| dimensions_mm |
590x440x320
|
| ip_rating |
IP21
|
| weight_kg |
19
|
Environment
| humidity_pct |
0-90
|
| operating_temperature_c |
-20 to +40
|
Interfaces & connectors
| communication_ports |
['RS485', 'RS232', 'LAN']
|
| lcd |
System type, PV voltage, charge voltage/current/power, temperature
|
| load_control_modes |
['Dual time control', 'PV voltage control', 'PV & time control', 'On/Off control']
|
Protection
| cooling |
Intelligent fan cooling
|
| design_lifespan_years |
10
|
| protections |
['Input low voltage', 'Over voltage', 'PV reverse connection', 'Battery reverse connection', 'Over discharge', 'Short-circuit', 'Over-temp']
|
Certifications
| standards |
['CE', 'RoHS', 'UL', '3C']
|
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| source.category | solar_charge_controller |