ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BasePV Modules

Canadian Solar CS6.1-54TD-470

Official manufacturer GLOBAL verified Sept. 3, 2026

Identity

category pv_modules
generation N-type TOPCon
manufacturer Canadian Solar
market_version PV Module Product Datasheet V1.4_EN
model CS6.1-54TD-470
mpn UNKNOWN
product_family TOPHiKu6 CS6.1-54TD-445|450|455|460|465|470
product_status active
region GLOBAL
release_year 2024
series TOPHiKu6
sku UNKNOWN
variant dual-glass monofacial (-TD)

Electrical

application_class UNKNOWN
bifacial False
bifaciality_factor_pct UNKNOWN
cell_technology TOPCon cells, 108 [2 X (9 X 6) ] half-cut, dual-glass (TOPHiKu6)
extra {'power_bins_w': [445, 450, 455, 460, 465, 470], 'power_bin_table': [{'pmax_w': 445, 'model': 'CS6.1-54TD-445', 'voc_v': 38.7, 'vmp_v': 32.8, 'isc_a': 14.48, 'imp_a': 13.59, 'efficiency_pct': 21.8}, {'pmax_w': 450, 'model': 'CS6.1-54TD-450', 'voc_v': 38.9, 'vmp_v': 33.0, 'isc_a': 14.55, 'imp_a': 13.66, 'efficiency_pct': 22.0}, {'pmax_w': 455, 'model': 'CS6.1-54TD-455', 'voc_v': 39.1, 'vmp_v': 33.2, 'isc_a': 14.61, 'imp_a': 13.72, 'efficiency_pct': 22.3}, {'pmax_w': 460, 'model': 'CS6.1-54TD-460', 'voc_v': 39.3, 'vmp_v': 33.4, 'isc_a': 14.69, 'imp_a': 13.78, 'efficiency_pct': 22.5}, {'pmax_w': 465, 'model': 'CS6.1-54TD-465', 'voc_v': 39.5, 'vmp_v': 33.6, 'isc_a': 14.77, 'imp_a': 13.85, 'efficiency_pct': 22.8}, {'pmax_w': 470, 'model': 'CS6.1-54TD-470', 'voc_v': 39.7, 'vmp_v': 33.8, 'isc_a': 14.86, 'imp_a': 13.91, 'efficiency_pct': 23.0}], 'nmot_bin_table': [{'pmax_w': 337, 'bin': 445, 'voc_v': 36.6, 'vmp_v': 31.0, 'isc_a': 11.68, 'imp_a': 10.85}, {'pmax_w': 340, 'bin': 450, 'voc_v': 36.8, 'vmp_v': 31.2, 'isc_a': 11.73, 'imp_a': 10.91}, {'pmax_w': 344, 'bin': 455, 'voc_v': 37.0, 'vmp_v': 31.4, 'isc_a': 11.78, 'imp_a': 10.96}, {'pmax_w': 348, 'bin': 460, 'voc_v': 37.2, 'vmp_v': 31.6, 'isc_a': 11.85, 'imp_a': 11.02}, {'pmax_w': 352, 'bin': 465, 'voc_v': 37.4, 'vmp_v': 31.8, 'isc_a': 11.91, 'imp_a': 11.07}, {'pmax_w': 355, 'bin': 470, 'voc_v': 37.6, 'vmp_v': 32.0, 'isc_a': 11.98, 'imp_a': 11.12}], 'cell_count': '108 [2 X (9 X 6) ]', 'cell_layout': '108 half-cut cells, 2 x (9 x 6)', 'fire_type': 'TYPE 38 (UL 61730) or CLASS C (IEC 61730)', 'bifacial_gain_note': 'Dual-glass but printed as monofacial; no bifaciality factor on the sheet.'}
imp_a 13.91
isc_a 14.86
max_reverse_current_a UNKNOWN
max_series_fuse_rating_a 25
max_system_voltage_label 1500V (IEC/UL)
max_system_voltage_v 1500
module_efficiency_pct 23.0
nmot {'pmax_w': 355, 'voc_v': 37.6, 'vmp_v': 32.0, 'isc_a': 11.98, 'imp_a': 11.12, 'conditions': 'NMOT: irradiance of 800 W/m2, spectrum AM 1.5, ambient temperature 20 degC, wind speed 1 m/s', 'note': '470 W bin.'}
nmot_c 41
nmot_label 41 +/- 3 degC
pmax_w 470
power_tolerance 0 ~ + 10 W
protection_class UNKNOWN
rated_power_w 470
stc_conditions Under Standard Test Conditions (STC) of irradiance of 1000 W/m2, spectrum AM 1.5 and cell temperature of 25 degC
temp_coeff_isc 0.05 %/degC
temp_coeff_pmax -0.29 %/degC
temp_coeff_voc -0.25 %/degC
vmp_v 33.8
voc_v 39.7

Physical / mechanical

backsheet n/a - dual glass
bypass_diodes 3
cable_cross_section_mm2 4.0
cable_length_mm portrait: 300 mm (+) / 200 mm (-); landscape: 1150 mm
connector_type T6 or MC4-EVO2 or MC4-EVO2A
depth_mm 30
dimensions_mm 1800 x 1134 x 30
frame Anodized aluminium alloy
frame_colour UNKNOWN
glass Front: 1.6 mm heat strengthened glass with anti-reflective coating; Back: 1.6 mm heat strengthened glass
glass_construction dual glass
glass_thickness_mm 1.6
junction_box IP68, 3 bypass diodes
length_mm 1800
weight_kg 22.7
width_mm 1134

Installation

clamp_requirements UNKNOWN
grounding UNKNOWN
max_installation_altitude_m UNKNOWN
mounting_methods UNKNOWN

Environment

ammonia UNKNOWN
fire_rating TYPE 38 (UL 61730) or CLASS C (IEC 61730)
hail UNKNOWN
max_static_load_front_pa UNKNOWN
max_static_load_rear_pa UNKNOWN
operating_temperature_c -40 to +85
pid UNKNOWN
salt_mist UNKNOWN
snow_load 5400 Pa
wind_load 2400 Pa

Certifications

standards ['UNKNOWN - certification block not captured in the fetched extract']

Warranty & service

annual_degradation_pct 0.4
first_year_degradation_pct 1.0
performance_years 30
product_years 12
retained_power_at_year UNKNOWN
retained_power_end_pct UNKNOWN

Documents

datasheet CS-Datasheet-TOPHiKu6 (TOPCon) CS6.1-54TD v1.4_EN rev V1.4_EN

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

Module Fire PerformanceTYPE 38 (UL 61730)
manufacturer_legal_entity_as_printedCSI Solar Co., Ltd.