ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BasePV Modules

LONGi LR5-54HTB-450M

Official manufacturer GLOBAL verified Sept. 3, 2026

Identity

category pv_modules
generation Hi-MO X6 Scientist (black / full-black variant)
manufacturer LONGi
market_version DC1500V (IEC/UL)
model LR5-54HTB-450M
mpn UNKNOWN
product_family LR5-54HTB 440~450M (Hi-MO X6 Scientist Black, 30/30 and 15 Frame)
product_status active
region GLOBAL
release_year 2023
series Hi-MO X6
sku UNKNOWN
variant black frame / full-black edition (EN Black datasheet)

Electrical

application_class UNKNOWN
bifacial UNKNOWN
bifaciality_factor_pct UNKNOWN
cell_technology HPBC (hybrid passivated back contact) monocrystalline, 108 cells (6x18), single glass (Hi-MO X6 platform). The datasheet itself prints no cell-type row; LONGi's Hi-MO X6 product pages describe the line as HPBC.
extra {'power_bins_w': [440, 445, 450], 'power_bin_table': [{'pmax_w': 440, 'model': 'LR5-54HTB-440M', 'voc_v': 39.83, 'vmp_v': 33.56, 'isc_a': 14.15, 'imp_a': 13.12, 'efficiency_pct': 22.5}, {'pmax_w': 445, 'model': 'LR5-54HTB-445M', 'voc_v': 40.03, 'vmp_v': 33.76, 'isc_a': 14.23, 'imp_a': 13.19, 'efficiency_pct': 22.8}, {'pmax_w': 450, 'model': 'LR5-54HTB-450M', 'voc_v': 40.23, 'vmp_v': 33.96, 'isc_a': 14.31, 'imp_a': 13.27, 'efficiency_pct': 23.0}], 'noct_bin_table': [{'pmax_w': 329, 'model': 'LR5-54HTB-440M', 'voc_v': 37.4, 'vmp_v': 30.62, 'isc_a': 11.43, 'imp_a': 10.75}, {'pmax_w': 333, 'model': 'LR5-54HTB-445M', 'voc_v': 37.58, 'vmp_v': 30.81, 'isc_a': 11.49, 'imp_a': 10.82}, {'pmax_w': 337, 'model': 'LR5-54HTB-450M', 'voc_v': 37.77, 'vmp_v': 30.99, 'isc_a': 11.55, 'imp_a': 10.88}], 'cell_count': '108 (6x18)', 'cell_layout': '108 (6x18)', 'fire_type': 'IEC Class C', 'bifacial_gain_note': 'No bifaciality statement or rear-gain table is printed on this datasheet.'}
imp_a 13.27
isc_a 14.31
max_reverse_current_a UNKNOWN
max_series_fuse_rating_a 25
max_system_voltage_label DC1500V (IEC/UL)
max_system_voltage_v 1500
module_efficiency_pct 23.0
nmot {'pmax_w': 337, 'voc_v': 37.77, 'vmp_v': 30.99, 'isc_a': 11.55, 'imp_a': 10.88, 'conditions': 'NOCT: AM1.5, 800W/m2, 20 degC ambient, 1 m/s', 'note': 'Top bin only.'}
nmot_c 45
pmax_w 450
power_tolerance 0 ~ 3%
protection_class Class II
rated_power_w 450
stc_conditions AM1.5, 1000W/m2, 25 degC
temp_coeff_isc 0.05 %/degC
temp_coeff_pmax -0.29 %/degC
temp_coeff_voc -0.23 %/degC
vmp_v 33.96
voc_v 40.23

Physical / mechanical

backsheet UNKNOWN
bypass_diodes UNKNOWN
cable_cross_section_mm2 4.0
cable_length_mm 4mm2 output cable; +/-1200mm length can be customized
connector_type UNKNOWN - no connector brand or type is printed on this datasheet; Installation Manual V17 only states 'Only connectors as the compatible model from same vendor can be mated together'
depth_mm 30
dimensions_mm 1722x1134x30
frame Anodized aluminum alloy frame
frame_colour black
glass Single glass, 3.2mm coated tempered glass
glass_construction single glass
glass_thickness_mm 3.2
junction_box IP68
length_mm 1722
weight_kg 20.8
width_mm 1134

Installation

clamp_requirements Clamp length >= 50mm (recommended >= 60mm); frame overlap 10-12mm; M8 bolt torque 14-18 N.m
grounding Bolt grounding: 'Align grounding clamp to the frame grounding hole. Use grounding bolt to go through the grounding clamp and frame'; grounding holes are 4.2mm diameter at the edge of the module's back-side frame
max_installation_altitude_m UNKNOWN - not specified in Installation Manual V17
mounting_methods Clamp mounting per LONGi PV Module Installation Manual V17: 'the length of the clamp be at least 50mm, the clamp must maintain an overlap of 10-12 mm with the frame'; recommended 'clamp length >= 60mm, the overlap of clamp and frame >=10mm'

Environment

ammonia UNKNOWN
fire_rating IEC Class C
hail 25mm Hailstone at the speed of 23m/s
max_static_load_front_pa 5400
max_static_load_rear_pa 2400
operating_temperature_c -40 to +85
pid UNKNOWN
salt_mist UNKNOWN
snow_load UNKNOWN
wind_load UNKNOWN

Certifications

standards ['IEC 61215', 'IEC 61730', 'UL 61730', 'ISO 9001:2015', 'ISO 14001:2015', 'ISO 45001:2018', 'IEC 62941']

Warranty & service

annual_degradation_pct 0.4
first_year_degradation_pct 1.5
performance_years 25
product_years 25
retained_power_at_year 25
retained_power_end_pct UNKNOWN

Documents

datasheet LR5-54HTB 440~450M (Hi-MO X6 Scientist Black, 30/30 and 15 Frame) - LONGi module datasheet rev V19 20230811
installation-manual LONGi PV Module Installation Manual V17 rev V17

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

Bolt torqueM8: 14-18 N.m
UL typeUL type 1 or 2

Build a system with this product