ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BasePV Modules

LONGi LR5-72HTH-585M

Official manufacturer GLOBAL verified Sept. 3, 2026

Identity

category pv_modules
generation Explorer (as printed in the datasheet filename and header)
manufacturer LONGi
market_version IEC/UL DC1500V
model LR5-72HTH-585M
mpn UNKNOWN
product_family LR5-72HTH 565~585M (Explorer, 30/30 and 15 frame)
product_status UNKNOWN
region GLOBAL
release_year UNKNOWN
series UNKNOWN - the fetched sheet prints no Hi-MO series name; LONGi and ENF list this code under Hi-MO 6 / Hi-MO X6 Explorer
sku UNKNOWN
variant monofacial single glass (3.2mm coated tempered glass)

Electrical

application_class UNKNOWN - no Class A row is printed
bifacial False
bifaciality_factor_pct not applicable (monofacial)
cell_technology UNKNOWN - the fetched datasheet prints no cell-technology name row (no HPBC / TOPCon / PERC wording was read). It states cell orientation '144 (6x24)' and single-glass construction.
extra {'power_bins_w': [565, 570, 575, 580, 585], 'power_bin_table': [{'pmax_w': 565, 'model': 'LR5-72HTH-565M', 'voc_v': 51.76, 'vmp_v': 43.61, 'isc_a': 14.01, 'imp_a': 12.96, 'efficiency_pct': 21.9}, {'pmax_w': 570, 'model': 'LR5-72HTH-570M', 'voc_v': 51.91, 'vmp_v': 43.76, 'isc_a': 14.07, 'imp_a': 13.03, 'efficiency_pct': 22.1}, {'pmax_w': 575, 'model': 'LR5-72HTH-575M', 'voc_v': 52.06, 'vmp_v': 43.91, 'isc_a': 14.14, 'imp_a': 13.1, 'efficiency_pct': 22.3}, {'pmax_w': 580, 'model': 'LR5-72HTH-580M', 'voc_v': 52.21, 'vmp_v': 44.06, 'isc_a': 14.2, 'imp_a': 13.17, 'efficiency_pct': 22.5}, {'pmax_w': 585, 'model': 'LR5-72HTH-585M', 'voc_v': 52.36, 'vmp_v': 44.21, 'isc_a': 14.27, 'imp_a': 13.24, 'efficiency_pct': 22.6}], 'nmot_bin_table': [{'pmax_w': 565, 'nmot_pmax_w': 422, 'voc_v': 48.6, 'vmp_v': 39.79, 'isc_a': 11.31, 'imp_a': 10.61}, {'pmax_w': 570, 'nmot_pmax_w': 426, 'voc_v': 48.74, 'vmp_v': 39.93, 'isc_a': 11.36, 'imp_a': 10.68}, {'pmax_w': 575, 'nmot_pmax_w': 430, 'voc_v': 48.88, 'vmp_v': 40.07, 'isc_a': 11.42, 'imp_a': 10.73}, {'pmax_w': 580, 'nmot_pmax_w': 433, 'voc_v': 49.02, 'vmp_v': 40.2, 'isc_a': 11.47, 'imp_a': 10.78}, {'pmax_w': 585, 'nmot_pmax_w': 437, 'voc_v': 49.16, 'vmp_v': 40.34, 'isc_a': 11.52, 'imp_a': 10.84}], 'cell_count': '144 (6x24)', 'cell_layout': '144 (6x24)', 'fire_type': 'IEC Class C', 'bifacial_gain_note': 'None - monofacial single-glass module.', 'packaging': "36pcs per pallet / 180pcs per 20'GP / 720pcs per 40'HC"}
imp_a 13.24
isc_a 14.27
max_reverse_current_a UNKNOWN
max_series_fuse_rating_a 25
max_system_voltage_label DC1500V (IEC/UL)
max_system_voltage_v 1500
module_efficiency_pct 22.6
nmot {'pmax_w': 437, 'voc_v': 49.16, 'vmp_v': 40.34, 'isc_a': 11.52, 'imp_a': 10.84, 'conditions': 'NOCT: AM1.5 800W/m2 20 degC 1m/s', 'note': '585M top bin only.'}
nmot_c 45
pmax_w 585
power_tolerance 0 ~ 3%
protection_class Class II
rated_power_w 585
stc_conditions AM1.5 1000W/m2 25 degC
temp_coeff_isc 0.05 %/degC
temp_coeff_pmax -0.29 %/degC
temp_coeff_voc -0.23 %/degC
vmp_v 44.21
voc_v 52.36

Physical / mechanical

backsheet UNKNOWN - no backsheet row printed
bypass_diodes UNKNOWN - the junction box row prints only 'IP68'
cable_cross_section_mm2 4.0
cable_length_mm +400 / -200mm; +/-1400mm length can be customized
connector_type UNKNOWN - no connector row is printed on this datasheet, and LONGi's installation manual V17 (which covers LR5-72HTH) names no connector brand or part number.
depth_mm 30
dimensions_mm 2278x1134x30
frame Anodized aluminum alloy frame
frame_colour UNKNOWN
glass Single glass, 3.2mm coated tempered glass
glass_construction single glass
glass_thickness_mm 3.2
junction_box IP68
length_mm 2278
weight_kg 27.2
width_mm 1134

Installation

clamp_requirements The clamp must maintain an overlap of 10-12 mm with the frame; the length of the clamp be at least 50mm (installation manual V17)
grounding The module frame must be grounded; grounding holes with the diameter of 4.2 mm (installation manual V17)
max_installation_altitude_m UNKNOWN - not stated in installation manual V17
mounting_methods Bolts Mounting and Clamps Mounting (installation manual V17, which lists LR5-72HTH among covered models)

Environment

ammonia UNKNOWN
fire_rating IEC Class C
hail 25mm Hailstone at the speed of 23m/s
max_static_load_front_pa 5400
max_static_load_rear_pa 2400
operating_temperature_c -40 to +85
pid UNKNOWN
salt_mist LONGi modules passed the IEC 61701 salt spray corrosion test (installation manual V17; severity level not stated)
snow_load UNKNOWN
wind_load UNKNOWN

Certifications

standards ['IEC 61215', 'IEC 61730', 'UL 61730', 'ISO9001:2015', 'ISO14001:2015', 'ISO45001:2018', 'IEC62941']

Warranty & service

annual_degradation_pct 0.4
first_year_degradation_pct 1.5
performance_years 25
product_years 15
retained_power_at_year 25
retained_power_end_pct UNKNOWN

Documents

datasheet LR5-72HTH 565~585M V2 (30/30 and 15 Frame) Explorer - LONGi module datasheet rev 20230926V19
installation-manual LONGi PV Module Installation Manual V17 rev V17

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

Application noteSuitable for Distribution Market
First Year Degradation<1.5%
Packaging36pcs per pallet / 180pcs per 20'GP / 720pcs per 40'HC