LONGi LR5-72HTH-600M
Official manufacturer GLOBAL verified Sept. 3, 2026
Identity
| category | pv_modules |
| generation | Scientist (as printed in the datasheet filename and header) |
| manufacturer | LONGi |
| market_version | IEC/UL DC1500V |
| model | LR5-72HTH-600M |
| mpn | UNKNOWN |
| product_family | LR5-72HTH 590~600M (Scientist, 30/30 and 15 frame) |
| product_status | UNKNOWN |
| region | GLOBAL |
| release_year | UNKNOWN |
| series | UNKNOWN - the fetched sheet prints no Hi-MO series name; LONGi and ENF list this code under Hi-MO X6 Scientist |
| sku | UNKNOWN |
| variant | monofacial single glass (3.2mm coated tempered glass), higher-power bin family |
Electrical
| application_class | UNKNOWN |
| bifacial | False |
| bifaciality_factor_pct | not applicable (monofacial) |
| cell_technology | UNKNOWN - the fetched datasheet prints no cell-technology name row. It states cell orientation '144 (6x24)' and single-glass construction. |
| extra | {'power_bins_w': [590, 595, 600], 'power_bin_table': [{'pmax_w': 590, 'model': 'LR5-72HTH-590M', 'voc_v': 52.51, 'vmp_v': 44.36, 'isc_a': 14.33, 'imp_a': 13.31, 'efficiency_pct': 22.8}, {'pmax_w': 595, 'model': 'LR5-72HTH-595M', 'voc_v': 52.66, 'vmp_v': 44.51, 'isc_a': 14.4, 'imp_a': 13.37, 'efficiency_pct': 23.0}, {'pmax_w': 600, 'model': 'LR5-72HTH-600M', 'voc_v': 52.81, 'vmp_v': 44.66, 'isc_a': 14.46, 'imp_a': 13.44, 'efficiency_pct': 23.2}], 'nmot_bin_table': [{'pmax_w': 590, 'nmot_pmax_w': 441, 'voc_v': 49.3, 'vmp_v': 40.48, 'isc_a': 11.57, 'imp_a': 10.9}, {'pmax_w': 595, 'nmot_pmax_w': 445, 'voc_v': 49.44, 'vmp_v': 40.62, 'isc_a': 11.63, 'imp_a': 10.97}, {'pmax_w': 600, 'nmot_pmax_w': 448, 'voc_v': 49.58, 'vmp_v': 40.75, 'isc_a': 11.68, 'imp_a': 11.0}], 'cell_count': '144 (6x24)', 'cell_layout': '144 (6x24)', 'fire_type': 'IEC Class C', 'bifacial_gain_note': 'None - monofacial single-glass module.', 'packaging': "36pcs per pallet / 180pcs per 20'GP / 720pcs per 40'HC"} |
| imp_a | 13.44 |
| isc_a | 14.46 |
| max_reverse_current_a | UNKNOWN |
| max_series_fuse_rating_a | 25 |
| max_system_voltage_label | DC1500V (IEC/UL) |
| max_system_voltage_v | 1500 |
| module_efficiency_pct | 23.2 |
| nmot | {'pmax_w': 448, 'voc_v': 49.58, 'vmp_v': 40.75, 'isc_a': 11.68, 'imp_a': 11.0, 'conditions': 'NOCT: AM1.5 800W/m2 20 degC 1m/s', 'note': '600M top bin only.'} |
| nmot_c | 45 |
| pmax_w | 600 |
| power_tolerance | 0 ~ 3% |
| protection_class | Class II |
| rated_power_w | 600 |
| stc_conditions | AM1.5 1000W/m2 25 degC |
| temp_coeff_isc | 0.05 %/degC |
| temp_coeff_pmax | -0.29 %/degC |
| temp_coeff_voc | -0.23 %/degC |
| vmp_v | 44.66 |
| voc_v | 52.81 |
Physical / mechanical
| backsheet | UNKNOWN - no backsheet row printed |
| bypass_diodes | UNKNOWN - the junction box row prints only 'IP68' |
| cable_cross_section_mm2 | 4.0 |
| cable_length_mm | +400 / -200mm; +/-1400mm length can be customized |
| connector_type | UNKNOWN - no connector row is printed on this datasheet, and LONGi's installation manual V17 (which covers LR5-72HTH) names no connector brand or part number. |
| depth_mm | 30 |
| dimensions_mm | 2278x1134x30 |
| frame | Anodized aluminum alloy frame |
| frame_colour | UNKNOWN |
| glass | Single glass, 3.2mm coated tempered glass |
| glass_construction | single glass |
| glass_thickness_mm | 3.2 |
| junction_box | IP68 |
| length_mm | 2278 |
| weight_kg | 27.2 |
| width_mm | 1134 |
Installation
| clamp_requirements | The clamp must maintain an overlap of 10-12 mm with the frame; the length of the clamp be at least 50mm (installation manual V17) |
| grounding | The module frame must be grounded; grounding holes with the diameter of 4.2 mm (installation manual V17) |
| max_installation_altitude_m | UNKNOWN - not stated in installation manual V17 |
| mounting_methods | Bolts Mounting and Clamps Mounting (installation manual V17, which lists LR5-72HTH among covered models) |
Environment
| ammonia | UNKNOWN |
| fire_rating | IEC Class C |
| hail | 25mm hailstone at 23m/s |
| max_static_load_front_pa | 5400 |
| max_static_load_rear_pa | 2400 |
| operating_temperature_c | -40 to +85 |
| pid | UNKNOWN |
| salt_mist | LONGi modules passed the IEC 61701 salt spray corrosion test (installation manual V17; severity level not stated) |
| snow_load | UNKNOWN |
| wind_load | UNKNOWN |
Certifications
| standards | ['IEC 61215', 'IEC 61730', 'UL 61730', 'ISO9001:2015', 'ISO14001:2015', 'ISO45001:2018', 'IEC62941'] |
Warranty & service
| annual_degradation_pct | 0.4 |
| first_year_degradation_pct | 1.5 |
| performance_years | 25 |
| product_years | 15 |
| retained_power_at_year | 25 |
| retained_power_end_pct | UNKNOWN |
Documents
datasheet
LR5-72HTH 590~600M V2 (30/30 and 15 Frame) Scientist - LONGi module datasheet
rev 20230811V19
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| First Year Degradation | <1.5% |
| Packaging | 36pcs per pallet / 180pcs per 20'GP / 720pcs per 40'HC |