Risen Energy RSM130-8-450M
Official manufacturer global verified Sept. 1, 2026
Identity
| category | pv_modules |
| manufacturer | Risen Energy |
| model | RSM130-8-450M |
| product_family | RSM130-8-430M~450M |
| product_status | active |
| region | global |
Electrical
| bifacial | False |
| cell_technology | Monocrystalline half-cut, 130 cells (5x13 + 5x13), 9BB, white backsheet. Datasheet states only 'Monocrystalline'; PERC vs HJT is NOT stated in the fetched document. |
| connector_type | Risen Twinsel PV-SY02, IP68 |
| dimensions_mm | 1894x1096x30 |
| electrical_extra | {'power_tolerance': '0~+3%', 'power_bins_w': [430, 435, 440, 445, 450], 'limiting_reverse_current_a': 20} |
| imp_a | 11.93 |
| isc_a | 12.65 |
| max_series_fuse_rating_a |
20
Risen RSM130-8-430M~450M Datasheet — 'Max Series Fuse Rating 20A'
|
| max_system_voltage_v | 1500 |
| module_efficiency_pct | 21.7 |
| rated_power_w | 450 |
| temp_coeff_isc_pct_per_c | 0.04 |
| temp_coeff_pmax_pct_per_c | -0.34 |
| temp_coeff_voc_pct_per_c | -0.25 |
| vmp_v | 37.74 |
| voc_v |
45.33
Risen RSM130-8-430M~450M Datasheet — STC table, RSM130-8-450M row
|
| weight_kg | 22.5 |
Physical / mechanical
| backsheet | White Back-sheet |
| cable_cross_section_mm2 | 4.0 |
| cable_length_mm | (+) 350 mm, (-) 230 mm |
| depth_mm | 30 |
| enclosure_material | Anodized Aluminium Alloy, Black |
| glass | High Transmission, Low Iron, Tempered ARC Glass (thickness not stated) |
| glass_construction | single glass + white backsheet |
| height_mm | 1894 |
| junction_box | Potted, IP68, 1500 VDC |
| junction_box_diodes | 3 Schottky bypass diodes |
| mounting_type | ['rooftop', 'ground'] |
| weight_kg | 22.5 |
| width_mm | 1096 |
Installation
| bolt_torque |
M8 16-20 N.m; M6 14-18 N.m (manual pp.18-19)
Risen Energy PV Module Installation Manual — pp.18-19
|
| clamp_requirements | clamp contact depth 7 mm <= D <= 10 mm, length >= 50 mm, thickness >= 3 mm (manual p.18) |
| design_load_note | Table values are laboratory static mechanical test loads; apply a 1.5 safety factor (manual pp.22-26) |
| grounding | phi 4 mm grounding hole, M4 x 12 mm bolt with star and plain washers, torque 4-8 N.m (manual p.32) |
| installation_humidity_range | < 85 % RH (manual p.14) |
| installation_temperature_range_c | recommended -20 to +50; extreme -40 to +85 (manual p.14) |
| minimum_clearance_to_surface_mm | 115 |
| minimum_tilt_deg | 10 |
| mounting_hole | phi 9 x 20 mm (M8 bolts), phi 7 x 10 mm (M6 bolts) (manual p.18) |
| mounting_methods | M8 or M6 bolt sets through frame holes, or >= 4 clamps (Risen installation manual pp.18-19) |
| short_side_mounting_note | 65 mm <= L1 <= 1/4 B with load limits front <= 1800 Pa, rear <= 1200 Pa (manual p.27) |
Environment
| hail_rating | UNKNOWN |
| max_static_load_front_pa | 5400 |
| max_static_load_rear_pa | 2400 |
| operating_temperature_c | -40 to +85 |
| salt_mist_resistance | IEC 61701 salt mist method 6 and method 8 referenced (manual p.15) |
Certifications
| other | ['IEC62941', 'ISO 9001:2015', 'ISO 14001:2015', 'ISO 45001:2018'] |
| safety | ['IEC61215:2016', 'IEC61730-1/-2:2016'] |
Warranty & service
| annual_degradation_pct | 0.55 |
| end_of_warranty_output_pct | 84.8 |
| first_year_degradation_pct | UNKNOWN |
| performance_years | 25 |
| standard_years | 12 |
Packaging & logistics
| units_per_20ft_container | 216 |
| units_per_40hq_container | 850 |
| units_per_pallet | 36 |