⚡ANMASystem BuildingAutomation, Network, Monitoring & Analytics
★PREMIUM

Knowledge Base › PV Modules

Trina Solar TSM-385DE09.05

Manufacturer documented NA

Identity

brand Trina Solar
category pv_modules
manufacturer Trina Solar
manufacturer_key trina
model TSM-385DE09.05
model_key tsm385de0905
product_family Vertex S TSM-DE09.05 380-400 W
product_status active
region NA
series Vertex S

Electrical

bifacial False
California Energy Commission PV module list, as published in NREL SAM library v2026.7.3 (commit 6ef6c5b, file sha256 a28cf895…) — CEC list row Name='Trina Solar TSM-385DE0905' (NREL SAM CEC Modules.csv)
cable_length_negative_mm 1100
Vertex S datasheet (NA edition; covers TSM-385DE09.05) — family-level datasheet row carried from officially-verified ANMA record trina/pv_modules/tsm400de0905@NA#backsheet-120-cell-1754x1096-mm-format (field electrical.cable_length_negative_mm); that NA-edition datasheet lists this power bin (electrical.extra.power_bins_w; range 380-400 in Vertex S TSM-DE09.05 380-400 W)
cable_length_positive_mm 1100
Vertex S datasheet (NA edition; covers TSM-385DE09.05) — family-level datasheet row carried from officially-verified ANMA record trina/pv_modules/tsm400de0905@NA#backsheet-120-cell-1754x1096-mm-format (field electrical.cable_length_positive_mm); that NA-edition datasheet lists this power bin (electrical.extra.power_bins_w; range 380-400 in Vertex S TSM-DE09.05 380-400 W)
cec_average_noct_c 44.3 °C
California Energy Commission PV module list, as published in NREL SAM library v2026.7.3 (commit 6ef6c5b, file sha256 a28cf895…) — CEC list row Name='Trina Solar TSM-385DE0905' (NREL SAM CEC Modules.csv)
cec_temp_coeff_isc_pct_per_c 0.037 %/°C inferred
California Energy Commission PV module list, as published in NREL SAM library v2026.7.3 (commit 6ef6c5b, file sha256 a28cf895…) — CEC list row Name='Trina Solar TSM-385DE0905' (NREL SAM CEC Modules.csv)
cec_temp_coeff_pmax_pct_per_c -0.317 %/°C
California Energy Commission PV module list, as published in NREL SAM library v2026.7.3 (commit 6ef6c5b, file sha256 a28cf895…) — CEC list row Name='Trina Solar TSM-385DE0905' (NREL SAM CEC Modules.csv)
cec_temp_coeff_voc_pct_per_c -0.237 %/°C inferred
California Energy Commission PV module list, as published in NREL SAM library v2026.7.3 (commit 6ef6c5b, file sha256 a28cf895…) — CEC list row Name='Trina Solar TSM-385DE0905' (NREL SAM CEC Modules.csv)
cell_count 120
Vertex S datasheet (NA edition; covers TSM-385DE09.05) — family-level datasheet row carried from officially-verified ANMA record trina/pv_modules/tsm400de0905@NA#backsheet-120-cell-1754x1096-mm-format (field electrical.cell_count); that NA-edition datasheet lists this power bin (electrical.extra.power_bins_w; range 380-400 in Vertex S TSM-DE09.05 380-400 W)
cell_technology Mono-c-Si
California Energy Commission PV module list, as published in NREL SAM library v2026.7.3 (commit 6ef6c5b, file sha256 a28cf895…) — CEC list row Name='Trina Solar TSM-385DE0905' (NREL SAM CEC Modules.csv)
cells_in_series 60
California Energy Commission PV module list, as published in NREL SAM library v2026.7.3 (commit 6ef6c5b, file sha256 a28cf895…) — CEC list row Name='Trina Solar TSM-385DE0905' (NREL SAM CEC Modules.csv)
imp_a 11.46 A
California Energy Commission PV module list, as published in NREL SAM library v2026.7.3 (commit 6ef6c5b, file sha256 a28cf895…) — CEC list row Name='Trina Solar TSM-385DE0905' (NREL SAM CEC Modules.csv)
isc_a 12.07 A
California Energy Commission PV module list, as published in NREL SAM library v2026.7.3 (commit 6ef6c5b, file sha256 a28cf895…) — CEC list row Name='Trina Solar TSM-385DE0905' (NREL SAM CEC Modules.csv)
junction_box_ip_rating IP68
Vertex S datasheet (NA edition; covers TSM-385DE09.05) — family-level datasheet row carried from officially-verified ANMA record trina/pv_modules/tsm400de0905@NA#backsheet-120-cell-1754x1096-mm-format (field electrical.junction_box_ip_rating); that NA-edition datasheet lists this power bin (electrical.extra.power_bins_w; range 380-400 in Vertex S TSM-DE09.05 380-400 W)
max_series_fuse_rating_a 20
Vertex S datasheet (NA edition; covers TSM-385DE09.05) — family-level datasheet row carried from officially-verified ANMA record trina/pv_modules/tsm400de0905@NA#backsheet-120-cell-1754x1096-mm-format (field electrical.max_series_fuse_rating_a); that NA-edition datasheet lists this power bin (electrical.extra.power_bins_w; range 380-400 in Vertex S TSM-DE09.05 380-400 W)
max_system_voltage_v 1500
Vertex S datasheet (NA edition; covers TSM-385DE09.05) — family-level datasheet row carried from officially-verified ANMA record trina/pv_modules/tsm400de0905@NA#backsheet-120-cell-1754x1096-mm-format (field electrical.max_system_voltage_v); that NA-edition datasheet lists this power bin (electrical.extra.power_bins_w; range 380-400 in Vertex S TSM-DE09.05 380-400 W)
mechanical_load_front_pa 6000
Vertex S datasheet (NA edition; covers TSM-385DE09.05) — family-level datasheet row carried from officially-verified ANMA record trina/pv_modules/tsm400de0905@NA#backsheet-120-cell-1754x1096-mm-format (field electrical.mechanical_load_front_pa); that NA-edition datasheet lists this power bin (electrical.extra.power_bins_w; range 380-400 in Vertex S TSM-DE09.05 380-400 W)
mechanical_load_rear_pa 4000
Vertex S datasheet (NA edition; covers TSM-385DE09.05) — family-level datasheet row carried from officially-verified ANMA record trina/pv_modules/tsm400de0905@NA#backsheet-120-cell-1754x1096-mm-format (field electrical.mechanical_load_rear_pa); that NA-edition datasheet lists this power bin (electrical.extra.power_bins_w; range 380-400 in Vertex S TSM-DE09.05 380-400 W)
module_efficiency_pct 20.16 % inferred
California Energy Commission PV module list, as published in NREL SAM library v2026.7.3 (commit 6ef6c5b, file sha256 a28cf895…) — CEC list row Name='Trina Solar TSM-385DE0905' (NREL SAM CEC Modules.csv)
noct_c 43.0
Vertex S datasheet (NA edition; covers TSM-385DE09.05) — family-level datasheet row carried from officially-verified ANMA record trina/pv_modules/tsm400de0905@NA#backsheet-120-cell-1754x1096-mm-format (field electrical.noct_c); that NA-edition datasheet lists this power bin (electrical.extra.power_bins_w; range 380-400 in Vertex S TSM-DE09.05 380-400 W)
ptc_rating_w 362.3 W
California Energy Commission PV module list, as published in NREL SAM library v2026.7.3 (commit 6ef6c5b, file sha256 a28cf895…) — CEC list row Name='Trina Solar TSM-385DE0905' (NREL SAM CEC Modules.csv)
rated_power_w 385.0 W
California Energy Commission PV module list, as published in NREL SAM library v2026.7.3 (commit 6ef6c5b, file sha256 a28cf895…) — CEC list row Name='Trina Solar TSM-385DE0905' (NREL SAM CEC Modules.csv)
temp_coeff_isc_pct_per_c 0.04
Vertex S datasheet (NA edition; covers TSM-385DE09.05) — family-level datasheet row carried from officially-verified ANMA record trina/pv_modules/tsm400de0905@NA#backsheet-120-cell-1754x1096-mm-format (field environment.temperature_coefficient_isc_percent_c); that NA-edition datasheet lists this power bin (electrical.extra.power_bins_w; range 380-400 in Vertex S TSM-DE09.05 380-400 W)
temp_coeff_pmax_pct_per_c -0.34
Vertex S datasheet (NA edition; covers TSM-385DE09.05) — family-level datasheet row carried from officially-verified ANMA record trina/pv_modules/tsm400de0905@NA#backsheet-120-cell-1754x1096-mm-format (field environment.temperature_coefficient_pmax_percent_c); that NA-edition datasheet lists this power bin (electrical.extra.power_bins_w; range 380-400 in Vertex S TSM-DE09.05 380-400 W)
temp_coeff_voc_pct_per_c -0.25
Vertex S datasheet (NA edition; covers TSM-385DE09.05) — family-level datasheet row carried from officially-verified ANMA record trina/pv_modules/tsm400de0905@NA#backsheet-120-cell-1754x1096-mm-format (field environment.temperature_coefficient_voc_percent_c); that NA-edition datasheet lists this power bin (electrical.extra.power_bins_w; range 380-400 in Vertex S TSM-DE09.05 380-400 W)
vmp_v 33.6 V
California Energy Commission PV module list, as published in NREL SAM library v2026.7.3 (commit 6ef6c5b, file sha256 a28cf895…) — CEC list row Name='Trina Solar TSM-385DE0905' (NREL SAM CEC Modules.csv)
voc_v 40.6 V
California Energy Commission PV module list, as published in NREL SAM library v2026.7.3 (commit 6ef6c5b, file sha256 a28cf895…) — CEC list row Name='Trina Solar TSM-385DE0905' (NREL SAM CEC Modules.csv)
warranty_performance_years 25
Vertex S datasheet (NA edition; covers TSM-385DE09.05) — family-level datasheet row carried from officially-verified ANMA record trina/pv_modules/tsm400de0905@NA#backsheet-120-cell-1754x1096-mm-format (field electrical.warranty_performance_years); that NA-edition datasheet lists this power bin (electrical.extra.power_bins_w; range 380-400 in Vertex S TSM-DE09.05 380-400 W)
warranty_product_years 25
Vertex S datasheet (NA edition; covers TSM-385DE09.05) — family-level datasheet row carried from officially-verified ANMA record trina/pv_modules/tsm400de0905@NA#backsheet-120-cell-1754x1096-mm-format (field electrical.warranty_product_years); that NA-edition datasheet lists this power bin (electrical.extra.power_bins_w; range 380-400 in Vertex S TSM-DE09.05 380-400 W)

Physical / mechanical

weight_kg 21.0
Vertex S datasheet (NA edition; covers TSM-385DE09.05) — family-level datasheet row carried from officially-verified ANMA record trina/pv_modules/tsm400de0905@NA#backsheet-120-cell-1754x1096-mm-format (field physical.weight_kg); that NA-edition datasheet lists this power bin (electrical.extra.power_bins_w; range 380-400 in Vertex S TSM-DE09.05 380-400 W)

Environment

operating_temperature_max_c 85
Vertex S datasheet (NA edition; covers TSM-385DE09.05) — family-level datasheet row carried from officially-verified ANMA record trina/pv_modules/tsm400de0905@NA#backsheet-120-cell-1754x1096-mm-format (field environment.operating_temperature_max_c); that NA-edition datasheet lists this power bin (electrical.extra.power_bins_w; range 380-400 in Vertex S TSM-DE09.05 380-400 W)
operating_temperature_min_c -40
Vertex S datasheet (NA edition; covers TSM-385DE09.05) — family-level datasheet row carried from officially-verified ANMA record trina/pv_modules/tsm400de0905@NA#backsheet-120-cell-1754x1096-mm-format (field environment.operating_temperature_min_c); that NA-edition datasheet lists this power bin (electrical.extra.power_bins_w; range 380-400 in Vertex S TSM-DE09.05 380-400 W)

Documents

certificate California Energy Commission PV module list, as published in NREL SAM library v2026.7.3 (commit 6ef6c5b, file sha256 a28cf895…)
datasheet Vertex S datasheet (NA edition; covers TSM-385DE09.05)
installation-manual Trina Solar installation manual