ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BasePv Optimizers

Huawei SUN2000-450W-P2

Official manufacturer GLOBAL verified Sept. 3, 2026

Identity

category pv_optimizers
generation previous generation (still listed on solar.huawei.com)
manufacturer Huawei
marketing_name Smart Module Controller / Smart PV Optimizer
model SUN2000-450W-P2
note Huawei publishes SUN2000-450W-P2 and SUN2000-600W-P on one combined datasheet and spec page.
product_family SUN2000-P
region GLOBAL
series_siblings ['SUN2000-450W-P2', 'SUN2000-600W-P']

Electrical

communication_protocol MBUS
max_efficiency_pct 99.5
max_input_current_a UNKNOWN
max_input_dc_power_w UNKNOWN
max_input_voltage_label Absolute max. input voltage
max_input_voltage_v 80
max_output_current_a 15
max_output_voltage_v 80
max_pv_module_power_rule_quote "*1: The maximum power of PV module at STC shall NOT exceed the 'Rated Input DC Power' of the power optimizer."
max_pv_module_power_stc_w 450
max_short_circuit_current_isc_a 14.5
mppt_operating_voltage_range_v 10 - 80
output_bypass True
output_impedance_during_standby 1 kΩ ± 10%
output_voltage_during_standby_v 0
overvoltage_category II
rated_input_dc_power_w 450
weighted_efficiency_pct 99.0

Physical / mechanical

dimensions_w_h_d_mm 75 mm x 140 mm x 28 mm (3.0 in. x 5.5 in. x 1.1 in.)
input_connector Staubli MC4
input_wire_length_m 0.15
output_connector Staubli MC4
output_wire_length_m 1.3
weight_basis including cables
weight_kg 0.6

Installation

deployment_rule UNKNOWN
deployment_rule_note No 'full optimizer configuration only' statement was found for this family in the fetched sources. Whether partial/selective deployment is supported is NOT_DOCUMENTED here; do not infer it.
max_optimizers_per_system UNKNOWN
mixing_rule_quote "*6 SUN2000-450W-P2/600W-P and MERC-1100/1300W-P can NOT be used in mixture under the same Smart Energy / PV Controller"
string_design_by_inverter [{'inverter': 'SUN2000-2~6KTL-L1', 'min_optimizers_per_string': 4, 'max_optimizers_per_string': 25, 'max_dc_power_per_string_w': 6000}, {'inverter': 'SUN5000-8/12K-MAP0', 'min_optimizers_per_string': 6, 'max_optimizers_per_string': 35, 'max_dc_power_per_string_w': 12000}, {'inverter': 'SUN2000-3~10KTL-M1', 'min_optimizers_per_string': 6, 'max_optimizers_per_string': 35, 'max_dc_power_per_string_w': 12000}, {'inverter': 'SUN2000-5/6/8/10/12K-MAP0', 'min_optimizers_per_string': 6, 'max_optimizers_per_string': 35, 'max_dc_power_per_string_w': 12000}, {'inverter': 'SUN2000-12~25KTL-M5', 'min_optimizers_per_string': 6, 'max_optimizers_per_string': 35, 'max_dc_power_per_string_w': 12000}, {'inverter': 'SUN2000-12~25K-MB0', 'min_optimizers_per_string': 6, 'max_optimizers_per_string': 35, 'max_dc_power_per_string_w': 12000}, {'inverter': 'SUN2000-30K/36K/40K-M3', 'min_optimizers_per_string': 6, 'max_optimizers_per_string': 25, 'max_dc_power_per_string_w': 12000}, {'inverter': 'SUN5000-17/25K-MB0', 'min_optimizers_per_string': 6, 'max_optimizers_per_string': 35, 'max_dc_power_per_string_w': 12000}]

Environment

degree_of_protection IP68
max_operating_altitude_m UNKNOWN
operating_humidity_pct_rh 0 - 100
operating_temperature_c -40 to +85

Interfaces & connectors

communication MBUS (power line communication over the PV string)

Protection

note This generation shuts down to 0 V with a 1 kΩ output impedance, unlike the MERC family which holds 1 V. Do not carry either figure across families.
rapid_shutdown UNKNOWN
shutdown_output_impedance 1 kΩ ± 10%
shutdown_output_voltage_v 0

Certifications

emc UNKNOWN
fire_safety VDE-AR-E 2100-712:2018-12
rohs True
safety IEC62109-1 (class II safety)

Warranty & service

standard_warranty_years UNKNOWN

Documents

datasheet SUN2000-450W-P2 / 600W-P Technical Specification (APAC) rev UNKNOWN
datasheet SUN2000-450W-P2 / SUN2000-600W-P Technical Specification rev 2022.07.12
spec_page SUN2000-450W-P2-600W-P Specs (product spec page) rev UNKNOWN

Recorded conflicts

documented_relationships (compatible inverter list) Review required
SUN2000-2~6KTL-L1, SUN5000-8/12K-MAP0, SUN2000-3~10KTL-M1, SUN2000-5/6/8/10/12K-MAP0, SUN2000-12~25KTL-M5, SUN2000-12~25K-MB0, SUN2000-30K/36K/40K-M3, SUN5000-17/25K-MB0 — https://solar.huawei.com/en/products/SUN2000-450W-P2-600W-P/specs/ (current spec page, PV System Design table)
SUN2000-2/3/3.68/4/4.6/5/6KTL-L1, SUN2000-3/4/5/6/8/10KTL-M1, SUN2000-12/15/17/20KTL-M2, SUN2000-30/36/40KTL-M3 — https://solar.huawei.com/-/media/Solar/attachment/pdf/apac/datasheet/P2%20Datasheet/SUN2000-450W-P2%20%20600W-P%20Datasheet.pdf
installation.string_design_by_inverter (SUN2000-3~10KTL-M1) Review required
min 6 / max 35 / 12,000 W per string — https://solar.huawei.com/en/products/SUN2000-450W-P2-600W-P/specs/ (current spec page)
min 4 / max 35 / 10,000 W per string — https://solar.huawei.com/-/media/Solar/datasheet/SUN2000450WP2SUN2000600WP.pdf (version 2022.07.12)
installation.string_design_by_inverter (SUN2000-2~6KTL-L1) Review required
min 4 / max 25 / 6,000 W per string — https://solar.huawei.com/en/products/SUN2000-450W-P2-600W-P/specs/ (current spec page)
min 6 / max 25 / 6,000 W per string — https://solar.huawei.com/-/media/Solar/datasheet/SUN2000450WP2SUN2000600WP.pdf (version 2022.07.12)

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

documented_relationship:inverter_optimizer{"to_manufacturer": "Huawei", "to_model": "SUN2000-2/3/3.68/4/4.6/5/6KTL-L1, SUN2000-3/4/5/6/8/10KTL-M1, SUN2000-12/15/17/20KTL-M2, SUN2000-30/36/40KTL-M3", "relationship_type": "inverter_optimizer", "match_level": "series", "communication_protocol": "MBUS", "required_firmware": "UNKNOWN", "required_settings": "See PDF PV System Design table", "required_accessories": "None documented", "region": "APAC / Global", "source": "Huawei SUN2000-450W-P2 & 600W-P datasheet (PDF)", "source_url": "https://solar.huawei.com/-/media/Solar/attachment/pdf/apac/datasheet/P2%20Datasheet/SUN2000-450W-P2%20%20600W-P%20Datasheet.pdf", "source_page": "Compatible inverter models", "confidence": "officially-verified", "status": "COMPATIBLE", "notes": "Older PDF list, retained alongside the current spec-page list because the two disagree. Includes SUN2000-12/15/17/20KTL-M2 which the current page omits."}
manufacturer_legal_entity_as_printedUNKNOWN

Build a system with this product