Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.

Identity

category pv_optimizers
generation previous generation (still listed on solar.huawei.com)
manufacturer Huawei
marketing_name Smart Module Controller / Smart PV Optimizer
model SUN2000-450W-P2
note Huawei publishes SUN2000-450W-P2 and SUN2000-600W-P on one combined datasheet and spec page.
product_family SUN2000-P
product_status active
region GLOBAL
series_siblings ['SUN2000-450W-P2', 'SUN2000-600W-P']

Electrical

communication_protocol MBUS
max_efficiency_pct 99.5
max_input_current_a —
max_input_dc_power_w —
max_input_voltage_label Absolute max. input voltage
max_input_voltage_v 80
max_output_current_a 15
max_output_voltage_v 80
max_pv_module_power_rule_quote "*1: The maximum power of PV module at STC shall NOT exceed the 'Rated Input DC Power' of the power optimizer."
max_pv_module_power_stc_w 450
max_short_circuit_current_isc_a 14.5
mppt_operating_voltage_range_v 10 - 80
official_manual_url https://support.huawei.com/enterprise/en/doc/EDOC1100218890
SUN2000-(600W-P, 450W-P2) Smart PV Optimizer Quick ... — search-index listing (query: SUN2000-450W-P optimizer user manual quick guide); document located, not fetched
official_product_url https://solar.huawei.com/en/products/SUN2000-450W-P2-600W-P/specs/
SUN2000-450W-P2-600W-P Specs (product spec page) — inventory record source_url
output_bypass True
output_impedance_during_standby 1 kΩ ± 10%
output_voltage_during_standby_v 0
overvoltage_category II
rated_input_dc_power_w 450
weighted_efficiency_pct 99.0

Physical / mechanical

dimensions_w_h_d_mm 75 mm x 140 mm x 28 mm (3.0 in. x 5.5 in. x 1.1 in.)
input_connector Staubli MC4
input_wire_length_m 0.15
output_connector Staubli MC4
output_wire_length_m 1.3
weight_basis including cables
weight_kg 0.6

Installation

deployment_rule —
deployment_rule_note No 'full optimizer configuration only' statement was found for this family in the fetched sources. Whether partial/selective deployment is supported is NOT_DOCUMENTED here; do not infer it.
max_optimizers_per_system —
mixing_rule_quote "*6 SUN2000-450W-P2/600W-P and MERC-1100/1300W-P can NOT be used in mixture under the same Smart Energy / PV Controller"
string_design_by_inverter [{'inverter': 'SUN2000-2~6KTL-L1', 'min_optimizers_per_string': 4, 'max_optimizers_per_string': 25, 'max_dc_power_per_string_w': 6000}, {'inverter': 'SUN5000-8/12K-MAP0', 'min_optimizers_per_string': 6, 'max_optimizers_per_string': 35, 'max_dc_power_per_string_w': 12000}, {'inverter': 'SUN2000-3~10KTL-M1', 'min_optimizers_per_string': 6, 'max_optimizers_per_string': 35, 'max_dc_power_per_string_w': 12000}, {'inverter': 'SUN2000-5/6/8/10/12K-MAP0', 'min_optimizers_per_string': 6, 'max_optimizers_per_string': 35, 'max_dc_power_per_string_w': 12000}, {'inverter': 'SUN2000-12~25KTL-M5', 'min_optimizers_per_string': 6, 'max_optimizers_per_string': 35, 'max_dc_power_per_string_w': 12000}, {'inverter': 'SUN2000-12~25K-MB0', 'min_optimizers_per_string': 6, 'max_optimizers_per_string': 35, 'max_dc_power_per_string_w': 12000}, {'inverter': 'SUN2000-30K/36K/40K-M3', 'min_optimizers_per_string': 6, 'max_optimizers_per_string': 25, 'max_dc_power_per_string_w': 12000}, {'inverter': 'SUN5000-17/25K-MB0', 'min_optimizers_per_string': 6, 'max_optimizers_per_string': 35, 'max_dc_power_per_string_w': 12000}]

Environment

degree_of_protection IP68
max_operating_altitude_m —
operating_humidity_pct_rh 0 - 100
operating_temperature_c -40 to +85
operating_temperature_max_c 60.0
operating_temperature_min_c -25.0

Interfaces & connectors

communication MBUS (power line communication over the PV string)

Protection

note This generation shuts down to 0 V with a 1 kΩ output impedance, unlike the MERC family which holds 1 V. Do not carry either figure across families.
rapid_shutdown —
shutdown_output_impedance 1 kΩ ± 10%
shutdown_output_voltage_v 0

Certifications

emc —
fire_safety VDE-AR-E 2100-712:2018-12
rohs True
safety IEC62109-1 (class II safety)

Warranty & service

standard_warranty_years —

Documents

datasheet SUN2000-450W-P2 / 600W-P Technical Specification (APAC) rev UNKNOWN
datasheet SUN2000-450W-P2 / SUN2000-600W-P Technical Specification rev 2022.07.12
quick-start SUN2000-(600W-P, 450W-P2) Smart PV Optimizer Quick ...
spec_page SUN2000-450W-P2-600W-P Specs (product spec page) rev UNKNOWN

Recorded conflicts

max_dc_power_per_string_w Review required
{'SUN2000-3~10KTL-M1': 12000} —
{'SUN2000-3-10KTL-M1': 10000} —
minimum_optimizers_per_string Review required
{'SUN2000-2~6KTL-L1': 4, 'SUN2000-3~10KTL-M1': 6, 'SUN2000-12~20KTL-M2/12~25KTL-M5': 6, 'SUN2000-30~40KTL-M3': 6} —
{'SUN2000-2-6KTL-L1': 6, 'SUN2000-3-10KTL-M1': 4, 'SUN2000-12-20KTL-M2': 6, 'SUN2000-30-40KTL-M3': 6} —
documented_relationships (compatible inverter list) Review required
SUN2000-2~6KTL-L1, SUN5000-8/12K-MAP0, SUN2000-3~10KTL-M1, SUN2000-5/6/8/10/12K-MAP0, SUN2000-12~25KTL-M5, SUN2000-12~25K-MB0, SUN2000-30K/36K/40K-M3, SUN5000-17/25K-MB0 — https://solar.huawei.com/en/products/SUN2000-450W-P2-600W-P/specs/ (current spec page, PV System Design table)
SUN2000-2/3/3.68/4/4.6/5/6KTL-L1, SUN2000-3/4/5/6/8/10KTL-M1, SUN2000-12/15/17/20KTL-M2, SUN2000-30/36/40KTL-M3 — https://solar.huawei.com/-/media/Solar/attachment/pdf/apac/datasheet/P2%20Datasheet/SUN2000-450W-P2%20%20600W-P%20Datasheet.pdf
installation.string_design_by_inverter (SUN2000-3~10KTL-M1) Review required
min 6 / max 35 / 12,000 W per string — https://solar.huawei.com/en/products/SUN2000-450W-P2-600W-P/specs/ (current spec page)
min 4 / max 35 / 10,000 W per string — https://solar.huawei.com/-/media/Solar/datasheet/SUN2000450WP2SUN2000600WP.pdf (version 2022.07.12)
installation.string_design_by_inverter (SUN2000-2~6KTL-L1) Review required
min 4 / max 25 / 6,000 W per string — https://solar.huawei.com/en/products/SUN2000-450W-P2-600W-P/specs/ (current spec page)
min 6 / max 25 / 6,000 W per string — https://solar.huawei.com/-/media/Solar/datasheet/SUN2000450WP2SUN2000600WP.pdf (version 2022.07.12)

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

documented_relationship:inverter_optimizer{"to_manufacturer": "Huawei", "to_model": "SUN2000-2/3/3.68/4/4.6/5/6KTL-L1, SUN2000-3/4/5/6/8/10KTL-M1, SUN2000-12/15/17/20KTL-M2, SUN2000-30/36/40KTL-M3", "relationship_type": "inverter_optimizer", "match_level": "series", "communication_protocol": "MBUS", "required_firmware": "UNKNOWN", "required_settings": "See PDF PV System Design table", "required_accessories": "None documented", "region": "APAC / Global", "source": "Huawei SUN2000-450W-P2 & 600W-P datasheet (PDF)", "source_url": "https://solar.huawei.com/-/media/Solar/attachment/pdf/apac/datasheet/P2%20Datasheet/SUN2000-450W-P2%20%20600W-P%20Datasheet.pdf", "source_page": "Compatible inverter models", "confidence": "officially-verified", "status": "COMPATIBLE", "notes": "Older PDF list, retained alongside the current spec-page list because the two disagree. Includes SUN2000-12/15/17/20KTL-M2 which the current page omits."}
image_enrichment_pass2026-09-11
manufacturer_legal_entity_as_printedUNKNOWN