ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseSmart Meters

CHINT DTSU666 (and DTSU666-CT variant)

Official manufacturer GLOBAL verified Aug. 31, 2026

Identity

category smart_meters
manufacturer CHINT
model DTSU666 (and DTSU666-CT variant)
region GLOBAL

Electrical

ac_supply_frequency 50Hz
ac_supply_voltage 100-265V
accuracy_class Active power Class 1; Reactive power Class 2 (Deye Energy Meter page)
ct_ratio N/A base (direct to 80A); DTSU666-CT is CT-based for higher-capacity installs
deye_pairing Sold by Deye as one of its five approved energy meters (Deye 'Energy Meter' accessory page). Deye's own SUN-5/6/8/10/12K-SG04LP3-EU user manual (2025-11-15) offers 'Meter Select / No Meter 0/3 / CHNT / Eastron' in the inverter menu (p.43) and shows the CHINT meter wiring on pp.22-23.
direct_measurement_phase_to_neutral 100-265V
direct_voltage_measurement_between_phases 176-458V
export_limitation_support True
max_current_a 80
max_devices_on_bus 32
measurement_type direct (base 80A); CT-based (DTSU666-CT)
modbus_rtu True
modbus_tcp False
phase_type three-phase, four-wire
power_consumption <=1.5W / 6VA
rs485 True
supported_inverter_brands_models ['Deye (official zero-export meter, Deye-hosted manual PDF)', 'Sungrow ("Sungrow Three-Phase Smart Energy Meter DTSU666-20 CT")', 'Huawei (base hardware for the rebranded DTSU666-H, unconfirmed)']

Physical / mechanical

depth_mm 66
height_mm 72
mounting_type ['DIN-rail']
weight_kg 0.44
width_mm 100

Environment

ip_rating IP51
operating_temperature_c -25 to +55 (Deye page 'Regulated working temperature range')
relative_humidity <=75%
storage_temperature_c -40 to +70 ('Limited working temperature range')

Controls & display

display_type LCD
local_display True

Warranty & service

conditions Deye Energy Meter page row 'Warranty | 1.5 years' (Deye's accessory warranty, not CHINT's)
standard_years 1.5

Documents

datasheet Deye Energy Meter product page (HTML technical specification table for CHNT DDSU666, CHNT DTSU666, EASTRON SDM 230 Modbus, SDM 630-Modbus V2, SDM 630 MCT V2)
datasheet Deye accessory service guide - energy meters
user-manual {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} CHINT three-phase instruction manual DT(S)SU666 Y0.464.1002 V1.5 (hosted by Deye) — located, not retrieved rev V1.5 (2019-06-17)
user-manual Deye Hybrid Inverter User Manual SUN-5/6/8/10/12K-SG04LP3-EU (2025-11-15) rev 2025-11-15

Build a system with this product