⚡ANMASystem BuildingAutomation, Network, Monitoring & Analytics
★PREMIUM

Knowledge Base › Smart Meters

Eastron SDM120CT-MV

Official manufacturer GLOBAL verified Sept. 23, 2026

Identity

category smart_meters
manufacturer Eastron
model SDM120CT-MV
product_status active
region GLOBAL

Electrical

accuracy_class Class 1 (IEC 62053-21) / Class B (EN 50470-3)
baud_rate 1200bps~9600bps
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
bidirectional True
bidirectional_metering True
ct_secondary_current_a 0.1 A or 0.04 A (the meter also accepts a 100 mV voltage-output CT)
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
ct_secondary_options 100mV / 100mA / 40mA
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
display LCD with backlit
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
ethernet_port_count 0
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
local_modbus_available True
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
max_current_a 100.0
measured_values kWh, W, V, A, PF, Hz, demand
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
measurement_directions bidirectional
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
measurement_system 1P2W
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
measurement_type Current Transformer (CT)
meter_type CT-operated single-phase multi-function DIN-rail energy meter with mV/mA CT inputs
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
modbus_address_range 1~247
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
operating_voltage_range 80%~120% of Un
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
parity None (default), Odd, Even
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
phase_count 1
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
physical_interfaces ['RS485', 'pulse outputs']
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
pulse_output_count 2
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
rated_voltage_v 230
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
response_time <100 mS
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
stop_bits 1 or 2
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
supported_ct_ratios CT primary 1-9999 A, programmable
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
transmission_distance_m 1000
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
voltage_rating_v 230.0

Physical / mechanical

form_factor 1 Module, 18 mm width
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
mounting DIN-rail

Environment

operating_temperature_max_c 60.0
operating_temperature_min_c -25.0

Interfaces & connectors

communication RS485 Modbus RTU
documented_ports [{'port_role': 'RS485', 'port_label_from_manual': 'RS485 Modbus', 'port_type': 'terminal', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 1, 'document': 0, 'page': 'Specifications', 'quote': 'Output | 2 Pulse Output + RS485 Modbus; Communication Protocol | RS485 MODBUS RTU'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'Pulse Output', 'port_type': 'terminal', 'direction': 'output', 'electrical_domain': 'communication', 'quantity': 2, 'document': 0, 'page': 'Specifications', 'quote': 'Output | 2 Pulse Output + RS485 Modbus'}, {'port_role': 'CT', 'port_label_from_manual': 'CT input (mV/mA)', 'port_type': 'terminal', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 1, 'document': 0, 'page': 'Specifications', 'quote': 'Input - CT Secondary | 100mV / 100mA / 40mA; Input - CT Primary | 1-9999A'}]
protocols ['Modbus RTU']
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter
rs485 True
wifi False
Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter

Documents

manual Eastron SDM120CT-MV User Manual V1.6
product_page Eastron SDM120CT-MV RS485 Modbus CT Type mV/mA input Single Phase Multi-function Energy Meter

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

builder_completenesspartial
region_notesEastron's global English product page; 230 V rated. ANMA's existing Eastron records use region GLOBAL.
withheld:direct_current_max_a"not applicable - CT-operated meter"
withheld:internet_required_for_operation"not applicable - standalone meter"
withheld:max_connected_devices"not applicable - end device"
withheld:rs485_port_count1