ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseTransformer Stations

Huawei STS-3000K-H1

Manufacturer documented Global verified Sept. 3, 2026

Identity

category transformer_stations
hardware_revision UNKNOWN
manufacturer Huawei
manufacturer_legal_entity_as_printed UNKNOWN
market_version UNKNOWN
model STS-3000K-H1
product_family Huawei Smart Transformer Station
product_status UNKNOWN
product_status_evidence Datasheet served from solar.huawei.com under the Grid Forming ESS navigation crawled 2026-09-03; no lifecycle statement printed.
product_type_as_printed Smart Transformer Station
region Global
release_year UNKNOWN
sku_order_code UNKNOWN
variant_note 'STS-3000K-H1' — model number says 3000K while printed AC power is 3,400 kVA @40°C; recorded as printed.

Electrical

ac_power_rating 3,400 kVA @40°C
main_switch ACB (per-model value not resolvable from the fetched extract)
max_lv_ac_inputs 17
no_pv_input_note No PV input of any kind; this unit accepts LV AC from external inverters/PCS. num_mppt 0 is documented architecture.
nominal_frequency 50 Hz / 60 Hz
num_mppt 0
num_pv_inputs 0
rated_input_voltage 800 V (LV side)
rated_output_voltage 10 ~ 35 kV (MV side)
transformer_cooling ONAN
transformer_type Oil-immersed, Conservator Type
vector_group Dy11-y11 / Dy11

Physical / mechanical

cooling ONAN (transformer)
dimensions_w_h_d_mm 6,058 x 2,896 x 2,438 mm (20' HC ISO Container)
internal_arc_classification IAC A 20 kA 1s
ip_rating IP 54
noise_db UNKNOWN
weight < 15 t

Installation

commissioning_app UNKNOWN
mounting Containerised, foundation-mounted

Environment

max_altitude_m 1,000 m
operating_temperature -25 °C ~ 60 °C
relative_humidity 0% ~ 95% (Non-condensing)
storage_temperature UNKNOWN

Interfaces & connectors

ethernet UNKNOWN
local_api_availability UNKNOWN
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
rs485 UNKNOWN
smartlogger_compatibility UNKNOWN

Protection

afci UNKNOWN
anti_islanding UNKNOWN
internal_arc IAC A 20 kA 1s
mv_relay_protection 50/51, 50N/51N
rcmu UNKNOWN
spd UNKNOWN
transformer_monitoring Oil Level, Temperature, Pressure, Buchholz detection

Certifications

grid_codes UNKNOWN
standards IEC 62271-202, EN 50588-1, IEC 60076, IEC 62271-200, IEC 61439-1

Warranty & service

standard_warranty UNKNOWN

Documents

datasheet JUPITER-9000K-H0 / STS-6000K-H1 / STS-3000K-H1 Smart Transformer Station Datasheet rev UNKNOWN

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

manufacturer_legal_entity_as_printedUNKNOWN